HR-01 Pre-Installation Note
Understanding default pre-installation for HR-01 editions.
⏱️ Read Time: 2 minutes
Overview
🔶 HR-01-2 Edition and 🔷 HR-01-4 Edition systems ship with compute nodes already installed.
This is a brief reference note explaining what was completed by default. You do not need to perform these installation steps.
What Was Pre-Installed
By Default
Your HR-01 Edition EDC was assembled and tested before shipping:
Compute Nodes:
- HR-01 Edge Server nodes mounted in compute drawer
- Securely fastened with appropriate hardware
- Positioned and aligned for optimal cooling
Power Connections:
- Power cables connected from PDU to each node
- Power harnesses routed and secured
- Cable management completed
Network Connections:
- Ethernet cables connected from switch to each node
- RJ45 connections: 2× per node
- SFP+ connections: 2× per node (HR-01 models)
- Cables routed via keystone panel
- All connections labeled
System Testing:
- Power-on test performed
- Network connectivity verified
- Basic functionality confirmed
- System powered down for shipping
What You Should Know
Component Layout
HR-01-2 Edition:
- 2× HR-01 Edge Server nodes in compute drawer
- Nodes labeled 1 and 2
- Identical mounting and connection method
HR-01-4 Edition:
- 4× HR-01 Edge Server nodes in compute drawer
- Nodes labeled 1, 2, 3, and 4
- High-density configuration
Access:
- Open front lid to view compute drawer
- Pull drawer handle to slide out for inspection
- Do not remove nodes unless performing service
Physical Installation Details
If you need to understand the physical installation (for future service or replacements):
Mounting:
- HR-01 nodes mount similarly to NUC installation
- Larger form factor (full-depth servers vs compact NUCs)
- Secured with mounting screws
- Cooling clearances maintained
Power:
- Each node connects to PDU via power cable
- PDU outlets numbered and labeled
- Power distribution pre-balanced
Network:
- 2× RJ45 connections per node (to switch ports)
- 2× SFP+ connections per node (with copper transceivers included)
- Pre-wired through keystone panel on rear
- All keystone jacks labeled for tracing
Process is similar to NUC installation with adaptations for HR-01 form factor. See NUC Installation for general installation concepts (mounting, cabling method, power supply installation).
Differences from NUC Installation
Key differences between HR-01 and NUC editions:
| Aspect | NUC Edition | HR-01 Editions |
|---|---|---|
| Shipping State | Nodes NOT Installed | Nodes PRE-Installed |
| Node Count | 3× NUCs | 2× or 4× HR-01 Servers |
| Form factor | Compact NUC | Higher Storage and Compute Capacity Servers |
| Installation Required | Yes (Partner/Technical User) | No (Complete By Default) |
| Power Connections | 3× Cables | 2× or 4× Cables |
| Network Connections | 2× RJ45 Per Node | 2× RJ45 + 2× SFP+ Per Node |
What You Should Do Instead
Since your HR-01 edition is pre-installed:
Skip hardware installation and proceed directly to:
👉 Power & Startup - Power on the system
Then continue through:
Support and Documentation
For HR-01 Specific Information:
- StorMagic SvHCI documentation (if using StorMagic)
- Contact your reseller/partner for technical questions
What's Next?
HR-01 Edition Users Should Proceed To:
👉 Power & Startup - Connect power and perform first boot